DOWNLOAD the newest PDFVCE 2V0-13.24 PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=19u9pC4s-4bJDh_0ZywdEWSZzat69nig4
In the past ten years, our company has never stopped improving the VMware Cloud Foundation 5.2 Architect exam cram. For a long time, we have invested much money to perfect our products. At the same time, we have introduced the most advanced technology and researchers to perfect our VMware Cloud Foundation 5.2 Architect exam questions. At present, the overall strength of our company is much stronger than before. We are the leader in the market and master the most advanced technology. In fact, our 2V0-13.24 Test Guide has occupied large market shares because of our consistent renovating. We have built a powerful research center and owned a strong team. Up to now, we have got a lot of patents about the 2V0-13.24 test guide. In the future, we will continuously invest more money on researching.
You can get prepared with our VMware 2V0-13.24 exam materials only for 20 to 30 hours before you go to attend your exam. we can claim that you will achieve guaranteed success with our 2V0-13.24 study guide for that our high pass rate is unmarched 98% to 100%. And all the warm feedback from our clients proved our strength, you can totally relay on us with our VMware 2V0-13.24 practice quiz!
Our 2V0-13.24 exam cram is famous for instant access to download, and you can receive the downloading link and password within ten minutes, and if you don’t receive, you can contact us. Moreover, 2V0-13.24 exam materials contain both questions and answers, and it’s convenient for you to check the answers after practicing. We offer you free demo to have a try before buying, so that you can know what the complete version is like. We offer you free update for 365 days for 2V0-13.24 Exam Dumps, so that you can obtain the latest information for the exam, and the latest version for 2V0-13.24 exam dumps will be sent to your email automatically.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
NEW QUESTION # 57
The following storage design decisions were made:
DD01: A storage policy that supports failure of a single fault domain being the server rack.
DD02: Each host will have two vSAN OSA disk groups, each with four 4TB Samsung SSD capacity drives.
DD03: Each host will have two vSAN OSA disk groups, each with a single 300GB Intel NVMe cache drive.
DD04: Disk drives capable of encryption at rest.
DD05: Dual 10Gb or higher storage network adapters.
Which two design decisions would an architect include in the physical design? (Choose two.)
Answer: A,D
Explanation:
In VMware Cloud Foundation (VCF) 5.2, thephysical designspecifies tangible hardware and infrastructure choices, while logical design includes policies and configurations. The question focuses on vSAN Original Storage Architecture (OSA) in a VCF environment. Let's classify each decision:
Option A: DD01 - A storage policy that supports failure of a single fault domain being the server rack This is a logical design decision. Storage policies (e.g., vSAN FTT=1 with rack awareness) define data placement and fault tolerance, configured in software, not hardware. It's not part of the physical design.
Option B: DD02 - Each host will have two vSAN OSA disk groups, each with four 4TB Samsung SSD capacity drives This is correct. This specifies physical hardware-two disk groups per host with four 4TB SSDs each (capacity tier). In vSAN OSA, capacity drives are physical components, making this a physical design decision for VCF hosts.
Option C: DD03 - Each host will have two vSAN OSA disk groups, each with a single 300GB Intel NVMe cache drive This is correct. This details the cache tier-two disk groups per host with one 300GB NVMe drive each.
Cache drives are physical hardware in vSAN OSA, directly part of the physical design for performance and capacity sizing.
Option D: DD04 - Disk drives capable of encryption at rest
This is a hardware capability but not strictly a physical design decision in isolation. Encryption at rest (e.g., SEDs) is enabled via vSAN configuration and policy, blending physical (drive type) and logical(encryption enablement) aspects. In VCF, it's typically a requirement or constraint, not a standalone physical choice, making it less definitive here.
Option E: DD05 - Dual 10Gb or higher storage network adapters
This is a physical design decision (network adapters are hardware), but in VCF 5.2, storage traffic (vSAN) typically uses the same NICs as other traffic (e.g., management, vMotion) on a converged network. While valid, DD02 and DD03 are more specific to the storage subsystem's physical layout, taking precedence in this context.
Conclusion:The two design decisions for the physical design areDD02 (B)andDD03 (C). They specify the vSAN OSA disk group configuration-capacity and cache drives-directly shaping the physical infrastructure of the VCF hosts.
References:
VMware Cloud Foundation 5.2 Architecture and Deployment Guide (Section: vSAN OSA Design) VMware vSAN 7.0U3 Planning and Deployment Guide (integrated in VCF 5.2): Physical Design Considerations VMware Cloud Foundation 5.2 Planning and Preparation Guide (Section: Storage Hardware)
NEW QUESTION # 58
A customer has a database cluster running in a VCF cluster with the following characteristics:
40/60 Read/Write ratio.
High IOPS requirement.
No contention on an all-flash OSA vSAN cluster in a VI Workload Domain.
Which two vSAN configuration options should be configured for best performance? (Choose two.)
Answer: B,E
Explanation:
The database cluster in a VCF 5.2 VI Workload Domain uses an all-flash vSAN Original Storage Architecture (OSA) cluster with a 40/60 read/write ratio, high IOPS needs, and no contention (implying sufficient resources). vSAN configuration impacts performance, especially for databases. Let's evaluate:
Option A: Flash Read Cache ReservationIn all-flash vSAN OSA, the cache tier (flash) serves writes, not reads, which are handled by the capacity tier (also flash). ThevSAN Planning and Deployment Guidenotes that Flash Read Cache Reservation is deprecated for all-flash configurations, as reads don't benefit from caching, making this irrelevant for performance here.
Option B: RAID 1RAID 1 (mirroring) replicates data across hosts, offering high performance and availability (FTT=1). For a 40/60 read/write workload with high IOPS, RAID 1 minimizes latency and maximizes throughput compared to erasure coding (e.g., RAID 5), as it avoids parity calculations. TheVCF
5.2 Architectural Guiderecommends RAID 1 for performance-critical workloads like databases, especially with no contention.
Option C: Deduplication and Compression disabledDisabling deduplication and compression avoids CPU overhead and latency from data processing, critical for high-IOPS workloads. ThevSAN Administration Guide advises disabling these for performance-sensitive applications (e.g., databases), as the 60% write ratio benefits from direct I/O over space efficiency, given no contention.
Option D: Deduplication and Compression enabledEnabling deduplication and compression reduces storage use but increases latency and CPU load, degrading performance for high-IOPS workloads. ThevSAN Planning and Deployment Guidenotes this trade-off, making it unsuitable here.
Option E: RAID 5RAID 5 (erasure coding) uses parity, reducing write performance due to calculations, which conflicts with the 60% write ratio and high IOPS needs. TheVCF 5.2 Architectural Guiderecommends RAID 5 for capacity optimization, not performance, favoring RAID 1 instead.
Conclusion:
B: RAID 1 ensures high performance for IOPS and write-heavy workloads.
C: Disabling deduplication and compression optimizes I/O performance.These align with vSAN best practices for all-flash database clusters in VCF 5.2.References:
VMware Cloud Foundation 5.2 Architectural Guide(docs.vmware.com): vSAN Configuration for Performance.
vSAN Planning and Deployment Guide(docs.vmware.com): RAID Levels and All-Flash Settings.
vSAN Administration Guide(docs.vmware.com): Deduplication and Compression Impact.
NEW QUESTION # 59
Which two actions are required to support business continuity in a VCF deployment?
(Choose two)
Response:
Answer: A,D
NEW QUESTION # 60
Which of the following should be part of the logical design when creating a VMware Cloud Foundation Workload Domain?
Response:
Answer: D
NEW QUESTION # 61
Which two actions can be performed to troubleshoot VMware Cloud Foundation's NSX issues?
(Choose two)
Response:
Answer: A,D
NEW QUESTION # 62
......
If you feel nervous about the exam, then you can try the 2V0-13.24 test materials of us, we will help you pass the exam successfully. 2V0-13.24 Soft test engine can stimulate the real exam environment, through this version, and you can have a better understanding what the real exam environment is like. Moreover, 2V0-13.24 test materials are high-quality and they cover the most knowledge points of the exam, and you can have a good command of the exam. We provide you with free update for 365 days after purchasing, and the update version will be sent to your email address automatically.
Exam 2V0-13.24 Fees: https://www.pdfvce.com/VMware/2V0-13.24-exam-pdf-dumps.html
P.S. Free & New 2V0-13.24 dumps are available on Google Drive shared by PDFVCE: https://drive.google.com/open?id=19u9pC4s-4bJDh_0ZywdEWSZzat69nig4